Search Results for supply air sensor hvac
NO - SGX Sensortech
1. Sensing resistance in air R 0 is measured under controlled ambient conditions, i.e. synthetic air at 23 ±5°C and 50 ± 10% RH for RED sensor and synthetic air at 23 ±5°C and ≤ 5% RH for OX sensor. Sampling test. 2. Sensitivity factor is defined as Rs in air divided by Rs at 60 ppm CO. Test conditions are 23 ± 5°C and 50 ± 10% RH.
Miniature Amplified Low Pressure Sensors
intended for use with non-corrosive, non-ionic working fluids such as air, dry gases and the like. The output of the device is ratiometric to the supply voltage and operation from any D.C. supply voltage between 4.5 and 5.5 vo lts. Low Pressure (1” H 2 O to 30 “ H 2 O) Sensors • 0 to 1” H 2 O to 0 to 30” H 2 O Pressure Ranges
Miniature Pressure Sensors
range. This series is intended for use with non-corrosive, non-ionic working fluids such as air, dry gases and the like. The H-GRADE is a high accuracy version of the millivolt output pressure sensors. The output of the device is ratiometric to the supply voltage and operation from any D.C. supply voltage. H-Grade Pressure Sensors
Telaire | CO2, Humidity & Dust Sensors
The Telaire T6743 Internal CO2 Sensor is a nondispersive infrared (NDIR) CO2 sensor that implements a single channel diffusion sampling method for automotive HVAC applications, including automatic fresh air control and safety sensing for CO2 refrigerants. ... the casing offers a number of combinations to meet the needs of range, supply voltage ...
Thermometrics | Temperature Sensors
Thermometrics ZTP-115ML Thermopile Infrared (IR) Sensor Module presents temperature-compensated single outputs via I²C with optics (silicon lens). It can also provide compatibility with the customer’s device without the need for recalibration. The ZTP-115ML uses 4-wire connections: two signals for I2C output, single power supply and ground.
Automotive Sensors | Engine Management
Thermometrics GE-1856 Intake Air Temperature Sensor (IAT) monitors the temperature of the incoming intake air for an engine and provides a signal output that is proportional to air temperature. This signal can be used as an input to provide a signal to an Engine Control Unit (ECU), which uses this information to adjust fuel delivery and ...
Smart Board with Metal Oxide Sensor For Ozone Monitoring - SGX Sensortech
Power supply 3.3 – 5 Vdc, nominal 5.0 V Current consumption 30 to 40 mA according to ... { C M Heater of sensor 1 M Overheating of sensor } This command drives the heating of the ozone gas sensor. In initial mode (after reset), sensor is operated. ... real air relative humidity and not the one of heated air around the sensor.
SSI Technologies, LLC
HVAC & Industrial. SSI Technologies, LLC line of Pressure Sensors are well suited for a variety of industrial and commercial applications including HVAC purposes. These compact and robust sensors measure pressure from 3 PSI to 7,500 PSI. Our MediaGauge™ line of sensors are ideal for use in many applications such as refrigeration & process ...
About - All Sensors
Ideal markets for All Sensors’ products include medical, military, industrial, and HVAC. Common applications include ventilators, spirometry, blood pressure monitoring, building monitoring systems, industrial automation, air speed, and leak detection. Pressure ranges are available as low as 0.25 inH2O and as high as 150 PSI.
The MiCS-6814 is a compact MOS sensor with three fully independent ...
±5°C and 50 ± 10% RH for RED sensor and synthetic air at 23 ±5°C and ≤ 5% RH for OX sensor. ... RED sensor/OX sensor/NH3 sensor Symbol Typ Min Max Unit Heating power PH 76/43/66 71/30/60 81/50/73 mW Heating voltage VH 2.4/1.7/2.2 ... while using a 5V power supply. Packaging The sensors are packaged in a tape and reel for
DLH Series Low Voltage Digital Pressure Sensors
sensor (the active state is while eoc pin is low). note. 9: the sensor is calibrated with a 3.3v supply however, an internal regulator allows a supply voltage of 1.68v to 3.6v to be used without affecting the overall specifications. this allows direct operation from a battery supply. parameter symbol min typ max units notes
Emissions, Safety and Comfort - Amphenol
based HVAC systems. Solar and Twilight With the increased number of automatic climate control systems seen in vehicles today, we supply solar and twilight sensors for use with both HVAC and lighting systems. The Thermometrics dual solar sensor provides solar readings that help control the HVAC system internal cabin temperature.
P51 Pressure Sensor - ssi-sensors.com
(Harnessed Sensor) -40 °C to 105 °C -40 °C to 105 °C -40 °C to 105 °C Proof Pressure 2X FS 2X FS 3X FS ... water, wastewater, hydrogen, nitrogen, and air.) Designed to be used in media isolated mediums. Agency Approvals & Certifications Output Type 0.5 - 4.5 V 1 - 5 V 4 - 20 mA Supply Voltage 5 ± 0.5 Volts 8 to 30 Volts 8 to 30 Volts ...
2 Sensor for Automotive Applications - amphenol-sensors.com
The Telaire Internal Carbon Dioxide (CO2) Sensor is a nondispersive infrared (NDIR) CO2 sensor that implements a single channel diffusion sampling method for automotive HVAC applications, including automatic fresh air control and safety sensing for CO2 refrigerants.
Telaire Air Quality Sensors
T6613-X Sensor Modules T6713-X Sensor Modules T6615-X Sensor Modules T6715-X Sensor Module Typical Use • Commercial Office Monitoring • Residential monitoring • Cinema • Exhibition Hall • Automotive sensing • Railway car monitoring • 24/7 Security suite • Agricultural applications (Indoor growing, green/glass house, pig shed)
Indoor Agriculture: Smart Greenhouse Environmental Monitoring and Control
Telaire has over 35 technology patents including ABC Logic™ and warrants single wavelength sensor calibration for the life of the sensor. Amphenol Advanced Sensors is a trusted OEM partner providing temperature, humidity, pressure, CO 2 and dust sensors to solution providers in the HVAC, automotive, industrial and healthcare markets.
MediaGauge™ Digital Gauge - ssi-sensors.com
The SSI MediaGauge™ family offers four models of digital pressure gauges – three are stand-alone 9 V battery operated, and one uses an external power supply. All MediaGauge TM digital pressure gauges contain a piezoresistive pressure sensing element, signal conditioning for temperature and calibration, a stainless steel input port, and a 4 ...