Search Results for matlab function to stop execution
Unknown - Temposonics
Here the sensor requires a start signal from a controller or interface card to initiate the measurement cycle. The sensor generates a stop signal at the end of the measurement cycle that is used to stop the controller’s counter clock.
2009 e BA EtherCAT - Temposonics®
• Check the position sensor function regularly and document the tests. • Before switching on the system, make sure that no danger can arise for persons due to starting machinery. Repairs
Operation Manual GTE Analog - Temposonics
such as plausibility checks, limit switches, EMERGENCY STOP systems, protective devices etc. are required. In the event of trouble, shut down the sensor and protect it against accidental operation. 2.3.1 Safety instructions for commissioning To maintain the sensor’s operability, it is mandatory to follow the instructions given below.
Temposonics
Temposonics® ET Start / Stop Data Sheet I 2 I ET SENSOR Robust, non-contact and wear free, the Temposonics® linear position sensors provide best durability and accurate position measurement solutions in harsh industrial environments. The position measurement accuracy is tightly controlled by the quality of the waveguide which is
Operation Manual R-Series V EtherCAT 552059 EN - Temposonics
In the event of trouble, shut down the sensor and protect it against accidental operation. To maintain the sensor's operability, it is mandatory to follow the instructions given below. 1. Protect the sensor against mechanical damage during installation and operation. 2. Do not open or dismantle the sensor.
PROTIMETER
TimberMaster is switched on by pressing and holding it for a few seconds. for 3 seconds. Unit turns off automatically after few minutes (can be set) when no key press is detected. The TimberMaster is calibrated for wood at 20°C (68°F).
Digital triaxial MEMS accelerometer and temperature sensor
Function Connector pin power 1 ground 2 signal + 3 signal - 4 shield 5 (housing) ELECTRICAL Power 6 - 24 VDC LED Indicator 1 (RGB) ENVIRONMENTAL AND MECHANICAL Dimensions 35mm dia. x 26 mm h Weight 75 grams Sealing IP67 Case material: upper lower A6061 aluminum 303 stainless steel Connector 4-socket M8 Mating connector 4-pin M8
LEAP OBT Socket | Amphenol Active Optics Products
The LEAP® OBT socket has been designed to host the LEAP OBT optical modules (standard & rugged). The socket is soldered onto the PCB. The socket is soldered via the corner solder pads and the electrical interfaces consists of 225 BGA solder balls.
T RSERIES - Temposonics
FUNCTION Position Information 25- or 24- bit Binary or Gray code Parallel/Serial Data Shift Register SSI Interface The diagram, right, illustrates the function of Temposonics R Series position sensors with Serial Synchronous Interface (SSI). The position of a magnet mounted on a machine is precisely determined by a time-based method (i.e., magne-
M12883 Qualified Relay Sockets - Amphenol PCDAmphenol PCD
Amphenol PCD’s Relay Sockets are qualified to MIL-PRF-12883 specification and have an amp range between 2 and 25. Offered in various types and configurations, they feature state of the art ultrasonically bonded interfaces between the dialectric components, eliminating air paths and providing protection against moisture and degradation.
Data Sheet R-Series V Powerlink 552008 - temposonics.com
6 Temposonics® R-Series V RH5 POWERLINK Data Sheet TECHNICAL DRAWING Fig. 2: Temposonics® RH5 with ring magnet RH5-M/S-A/V – RH5 with threaded fl ange M18×1.5-6g or ¾"-16 UNF-3A, example: Connection type D58 (connector outlet) MS/ER NS/RN 1 4 5 2 1 4 5 2 17 (0.67) Sensor electronics housing
Brief Instruction G-Series 551515 Rev D - Temposonics
In the event of trouble, shut down the sensor and protect it against accidental operation. To maintain the sensor’s operability, it is mandatory to follow the instructions given below. Protect the sensor against mechanical damage during installation and operation. Do not open or dismantle the sensor.
Data Sheet R-Series V RFV SSI - Temposonics
3 Temposonics® R-Series V RFV SSI TECHNICAL DATA 1/ With standard one shot of 16 μs 2/ Sensor with standard settings. Further information can be found in the operation manual R-Series V SSI (document part number: 552011) 3/ With position magnet # 251 416-2 4/ The flexible sensor element must be mounted in an appropriately shielded environment Output
Brief Instruction R-Series - Temposonics
In the event of trouble, shut down the sen-sor and protect it against accidental operation. To maintain the sensor operability, it is mandatory to follow the instructions given below. Protect the sensor against mechanical damage during installation and operation. Do not open or dismantle the sensor.
550596 B IMPORTANT - Read this before you begin programming!
Pin No. Wire Color Function A White DC Ground B - No Connection C Gray Return for Pin D D Pink Output #1 (Displacement) * 0 to 10 Vdc, 10 to 0 Vdc, 4 to 20 mA, 0 to 20 mA, 20 to 4 mA, or 20 to 0 mA E Red + 24 Vdc, Customer Supplied F - No Connection G Yellow Output #2 (Displacement or Velocity) * 0 to 10 Vdc, 10 to 0 Vdc, 4 to 20 mA, 20 to 4 mA,
TEMPOSONICS III
SPECIFICATIONS PARAMETER SPECIFICATION Measured Variable: Displacement, Velocity (magnitude only) Resolution: 16 bit or 0.025 mm, whichever is greater Non-Linearity: < ± 0.02% of full stroke or ± 0.05 mm, whichever is greater Repeatability: < ± 0.001% of full scale or ± 0.0025 mm, whichever is greater Hysteresis: < 0.004 mm Outputs: Voltage: 0 to 10 Vdc or +10 to 0 Vdc *; Minimum load ...
Temposonics
5 Temposonics® ET Start/Stop ATEX/IECEx/CEC/NEC/CCC Certified Operation Manal 2/ See also applicable MTS Sensors terms of sales and delivery on www.mtssensors.com 2.4 Safety instructions for use in explosion-hazardous areas The sensor has been designed for operation inside explosion-hazarded areas. It has been tested and left the factory in a condition in which it is
Temposonics® G-Series GP (ATEX) Position Sensors
Analog, Start/Stop Document Part No. Revision Language Download Operation Manual 551596 E: EN CE UL/CUL ATEX EAC Industrial Position Sensors Toggle Sub Menu. R-Series V Position Sensors Toggle Sub Menu. R-Series V RH5 R-Series V RP5 R-Series V RM5 R-Series V RFV R-Series V RDV ...
Operation Manual R-Series V SSI 552011 - temposonics.com
THE NEWV TION Temposonics ® R-Series V SSI Operation Manual Temposonics ® Magnetostrictive Linear Position Sensors
Data Sheet HE-Series Analog
Pin Function A VDC B GND C SIG DTM06-3S A B C Pin Function A VDC B GND C SIG Fig. 5: Cable assignment Cable / Wires Cable A BN VDC WH GND GN SIG 4 mA 0.5 V Signal HIGH Signal HIGH 20 mA 4.5 V ≥ 2 mm for: sensor + magnet + add cylinder tolerances Mechanical stroke Electrical stroke Stroke Signal Retracted piston Extended piston Fig. 8 ...