Search Results for huawei d14 12th gen
TEMPERATURE SWITCHES AND SENSORS - el-cab.com.pl
Order number overview 12 Accessories 16 Electronic temperature switches 18 Connectors and designs 19 Order number overview 20 Accessories 21 Electronic temperature sensors 22 Connectors and designs 23 Order number overview 24 Accessories 25 Screw-in resistors 26 Connectors and designs 29 Characteristics of sensor elements 31 Order number ...
REV DESCRIPTION DATE ECO BY APPR A3 A5 ADD COLOR OPTION 23NOV20 LOUIE TOMMY
ATT-1612-03 Hand Crimp Tool S&F Size 12/16 20-22AWG - - ATRT-100 Contact and Wedgelock Extraction Tool Universal Universal - Steel Silver AT11-310-1605 Contact Extraction Tool Universal Size 16 - Plastic Lt Blue A114017 Seal Plug Universal Size 12/16 - Thermoplastic White A114017-SR Seal Plug Universal Size 16 - Thermoplastic Black
TECHNICAL FEATURES - rfstechnologies.com
Wire, 12 pairs Single-Mode Fiber, DLC Connectors, 110 ft HB114-U6S12-110-LI REV : F REV DATE : 08 Sep 2021 www.rfstechnologies.com All values nominal unless tolerances provided; information contained in the present datasheet is subject to confirmation at time of ordering Page 3 of 6.
NovaSensor NPI-19 Series Digital Pressure Sensors I2C
2Digital Pressure Sensor I C | 5 Parameter Symbol Min. Typ. Max. Units SCL clock frequency f FCL 100 400 kHz Start condition hold time relative to SCL edge tHDSTA 0.1 µS Minimum SCL clock low width 1) t LOW 0.6 µS Minimum SCL clock high width 1) t HIGH 0.6 µS Start condition setup time relative to SCL edge t SUSTA 0.1 µS Data hold time on SDA relative to SCL edge tHDDAT 0 µS
1900ND02S2X00D - Amphenol Air LB
Connector 1900 Socket With grommet unsealed 78 socket contacts #22 Without polarizer, with contacts (version 1)
NovaSensor NPI-19 Series Digital Pressure Sensors I2C
2Digital Pressure Sensor I C | 5 Parameter Symbol Min. Typ. Max. Units SCL clock frequency f FCL 100 400 kHz Start condition hold time relative to SCL edge tHDSTA 0.1 µS Minimum SCL clock low width 1) t LOW 0.6 µS Minimum SCL clock high width 1) t HIGH 0.6 µS Start condition setup time relative to SCL edge t SUSTA 0.1 µS Data hold time on SDA relative to SCL edge tHDDAT 0 µS
-30% - amphenol.co.jp
• Size 12, 16 and 20 signal contacts • -65°C/+260° operating temperature • Available in Scoop Proof format (shell size 14 and over with size 20 contacts) Amphenol Ltd Thanet Way Whitstable Kent CT5 3JF Tel:+44 (0)1227 773200 info@amphenol.co.uk www.amphenol.co.uk-30%
00118163334 - Amphenol Air LB
Component carrier Junction block #20 Diode
00197722400 - Amphenol Air LB
Connector 1977 Male 50 contacts #20 With socket polarizer
CCD Professional - el-cab.com.pl
7 620 200 051 – CCD | 7 620 200 052 – CCD Bluetooth 2 Robert Bosch Car Multimedia GmbH | CM-PS/MKT Subject to technical modification | 04.2014
B175 High Chirp, 1kW, 20° Tilt, No Connector, DT
Support. Cables & Adapters. Mix and Match Cables 1kW; Mix and Match Cables 600W; Mix and Match CHIRP Cables; Transducer Identification. B744V/VL Newer Version
Fluid-Trac Focus Tube Adaptor - amphenolsensors.com
Contact SSI Technologies, LLC 3200 Palmer Drive, Janesville, WI 53546 ssi-sensors.com 1 (608) 757-2000 (ST]VMKLXl6 & .8IGLRSPSKMIW 11(2EVVERX] MT AAT: All SSI products are warranted against defective materials and workmanship for a period of one (1) year from the date of delivery to the original purchaser.
Connector 1900 Socket With grommet sealed 39 socket contacts #22 + 10 ...
Connector 1900 Socket With grommet sealed 39 socket contacts #22 + 10 socket contacts #16 Fitted with socket polarizers With not mounted polarizers, with contacts (version 2)
High Performance Thermal-Magnetic Circuit Breaker 437-
operating voltage DC 12 V or DC 24 V approx. 18 A or 12 A 10 ms < t ON < 20 ms / t OFF > 10 s < 20 ms Electrical remote re-connection (-FC) operating voltage DC 12 V or DC 24 V operating current approx. 30 A or 15 A max. pulse time 0.1 s < t ON < 1.2 s / t OFF > 60 s switching time < 100 ms
35599112787PSU - Amphenol Air LB
Receptacle 3559 Fitted with pin module SIME0910P (marking BACC)
SMA プラグ - ジャック 固定減衰器 18GHz|製品情報|アンフェノールジャパン株式会社 -航空宇宙・産業機器用コネクタ-
Xバンド(8-12GHz)、Kuバンド(12-18GHz)、Kバンド(18-26GHz)の使用に適しています。 2.92mm シリーズと接続互換性あり ; Φ1.2mm、2.2mm、3.6mmのセミリジッドケーブル、フレキシブルケーブルおよ びRG-316に適用
Psyclone™ Protimeter Thermo-Hygrometer Operating Manual
Introduction The Protimeter Psyclone thermo- hygrometer measures relative humidity with psychometric measurements, along with temperature. One button enables Start, Hold and OFF operation, and four arrow keys allow you to set up
Protimeter Speedy 2000 Series - amphenol-sensors.com
Moisture testers for soils, sands, powders, aggregates, concrete and masonry PROTIMETER Speedy ®
NovaSensor NPI-19 Series Digital Pressure Sensors I2C
2Digital Pressure Sensor I C | 5 Parameter Symbol Min. Typ. Max. Units SCL clock frequency f FCL 100 400 kHz Start condition hold time relative to SCL edge tHDSTA 0.1 µS Minimum SCL clock low width 1) t LOW 0.6 µS Minimum SCL clock high width 1) t HIGH 0.6 µS Start condition setup time relative to SCL edge t SUSTA 0.1 µS Data hold time on SDA relative to SCL edge tHDDAT 0 µS
EBY Electro - EB456AM Series - 5.08mm Spacing - SCREWLESS PLUGGABLE ...
Custom Terminal Blocks. Complete Design Services - Tell us your requirements and EBY can design the efficient, economical component you need.. Manufacturing For You - With EBY's manufacturing network, we can offer quantities and delivery times at very competitive prices.. With CAD/CAE, Solid Modeling and Rapid Prototype Techniques, our engineers can bring your concepts to life in as little as ...