PS1&PS4-VOC-2000-MOD TotalOrganicVolatileModule Datasheet - SGX Sensortech
PartNumber Range Resolution TVOCGasModule PS1-VOC-2000-MOD 0-2000ppm 0.1ppm TVOCGasModule PS4-VOC-2000-MOD 0-2000ppm 0.1ppm 4PinCable Module4PINcable
Ventostat T8100 NS and NSP Series CO2 Sensor
eliminates the need for manual calibration in most applications. • Lifetime CO 2 calibration guarantee when using ABC Logic™. • Mounting plate with two-piece terminal blocks provide quick, easy wiring. • Gas permeable, water resistant CO 2 diffusion filter prevents particulate and water contamination of the sensor.
Telaire T5100-LED Series - amphenol-sensors.com
eliminates the need for manual calibration in most applications. • Lifetime CO 2 calibration guarantee when using ABC Logic™. • Mounting plate with two-piece terminal blocks provide quick, easy wiring. The new Telaire T5100-LED series is a new low cost, high performing CO 2 transmitter for the building controls market.
Item # NX303HB3B, Push-Button Switches with Contact 3
Browse Item # NX303HB3B, Push-Button Switches with Contact 3 in the Amphenol NEXUS Technologies catalog including Item #,Item Name,Button Color,AC Rating,DC Rating,Type 7 Contact Arrangement,Mechanical Life,Plunger,Plunger Travel,Action,Operating For
Ventostat T8100 NS and NSP Series CO2 Sensor
eliminates the need for manual calibration in most applications. • Lifetime CO 2 calibration guarantee when using ABC Logic™. • Mounting plate with two-piece terminal blocks provide quick, easy wiring. • Gas permeable, water resistant CO 2 diffusion filter prevents particulate and water contamination of the sensor.
Thermometrics ZTP-115 Thermopile IR Sensor
Unit: mm Pin arrangement: 1. GND Thermistor 2. Thermopile 3. GND Thermopile 4 . Thermistor Outline of Sensor Packaging and Pin Arrangement (unit: mm)
ZTP-315 Thermometrics Thermopile IR Sensor
Outline of Sensor Package and Pin Arrangement [unit: mm] Pin Arrangement 1. GND Thermistor 2. Thermopile 3. Thermistor 4. GND Thermopile AAS-920-590A-03/2014
NovaSensor NPH Series Solid State Low Pressure Sensors
NPH Series - Specifications Parameter Value Units Notes Pressure Range 0 to 10 in H 2O (0 to 25 mbar) 0 to 2.5 kPa 0 to 1 psi (0 to 7 bar) 0 to 7 kPa 0 to 5 psi (0 to 0.34 bar) 0 to 30 kPa
Thermometrics ZTP-115 Thermopile IR Sensor
Unit: mm Pin arrangement: 1. GND Thermistor 2. Thermopile 3. GND Thermopile 4 . Thermistor Outline of Sensor Packaging and Pin Arrangement (unit: mm)
Amphenol
Page 4 of 4 Page 1 of 4 PROTIMETER Pterocarpus indicus G Pterocarpus soyauxii F Pterygota bequaertii A Quercus cerris E Quercus delegatensis C Quercus gigantean C
APC 8010 Poliermaschine APC 8010 Polishing Machine - amphenol-po.de
Title: APC 8010 Polierzubehör_Datenblatt_Data Sheet_2020 Author: Louisa Sölch Created Date: 11/5/2020 2:28:25 PM
APPLICATION NOTE - ardentconcepts.com
Manual Actuator Hex Nuts Socket . APPLICATION NOTE Ardent Concepts, Inc. 4 Merrill Industrial Drive Hampton, NH 03842 (603) 474-1760 Sales: info@ardentconcepts.com Technical: Support@ardentconcepts.com Page 2 04/23/2018 AE-AN-SC-001 REV A 4.2. Types of Maintenance 4.2.1.
Data Sheet GTE Analog - temposonics.com
2 5 3 1 2 4 Measurement cycle 1 Current pulse generates magnetic fi eld 2 Interaction with position magnet fi eld generates torsional strain pulse 3 Torsional strain pulse propagates 4 Strain pulse detected by converter 5 Time-of-fl ight converted into position Sensing element (waveguide) Position magnet (magnetic fi eld)
ZTP-135H Thermopile IR Sensor - amphenol-sensors.com
Parameter Limits Units Condition Min Typ Max Chip Size 1.8 x 1.8 mm2 Diaphragm Size 1.4 x 1.4 mm2 Active Area 0.7 x 0.7 mm2 Internal Resistance 42 60 78 kW 25°C
NovaSensor Medium and High Pressure MEMS Pressure Sensor Die
P883 Specifications Parameter Value Units Notes General Pressure Differential only 5, 500 psig Differential and absolute 15, 30, 70, 150, 300 psig / psia
ZTP-315 Thermometrics Thermopile IR Sensor
Outline of Sensor Package and Pin Arrangement [unit: mm] Pin Arrangement 1. GND Thermistor 2. Thermopile 3. Thermistor 4. GND Thermopile AAS-920-590A-03/2014
ZTP-115 Thermopile IR Sensor - amphenol-sensors.com
Parameter Limits Units Condition Min Typ Max Chip Size 1.8 x 1.8 mm2 Diaphragm Size 1.4 x 1.4 mm2 Active Area 0.7 x 0.7 mm2 Internal Resistance 42 60 78 kW 25°C
Telaire Ventostat T8100 NS and NSP Series CO2 Sensor
Telaire Ventostat™ T8100 NS and NSP Series CO2 Sensor User Instructions T63351-003 September 2014 Page 1 of 4 Amphenol Advanced Sensors ® Installing the Sensor
NovaSensor Medium and High Pressure MEMS Pressure Sensor Die
P883 Specifications Parameter Value Units Notes General Pressure Differential only 5, 500 psig Differential and absolute 15, 30, 70, 150, 300 psig / psia
ZTP-115 Thermopile IR Sensor - amphenol-sensors.com
Parameter Limits Units Condition Min Typ Max Chip Size 1.8 x 1.8 mm2 Diaphragm Size 1.4 x 1.4 mm2 Active Area 0.7 x 0.7 mm2 Internal Resistance 42 60 78 kW 25°C