Search Results for amp din41612
Model 103B11 Acoustic ICP® pressure sensor, 10 psi, 500 mV/psi ... - PCB
MOSFET source follower amplifier which reduces the output impedance to less than 100 Ohms allowing the driving of long cables and permitting operating directly into most readout instruments. Refer to Bulletin G-0001B, “General Guide to ICP® Instrumentation” for a detailed description of the built-in amplifier concept.
Model 685B0011A13 Electronic vibration switch, internal ICP ... - PCB
Provides dual 5 Amp Triac (SPST) or 10 Amp Form C (SPDT) relay outputs. Adjustable trip limits and time delay via single turn potentiometers. Accommodates normally open (NO) and normally closed (NC) wiring schemes. Continuous or latching switch action. Local reset button and remote reset capability.
Model 102A02 High resolution ICP® pressure sensor, 100 psi, 50 ... - PCB
sensitivity of 50 mV/psi and a low noise amplifier of 50 V peak noise. Thus, 50 V/50mV = .001 psi resolution The output bias voltage of the Model 112A23 is 5.0 volts, half the bias voltage of most PCB pressure sensors. This will cause the bias monitor meter on PCB power supplies to read at the low end of the ...
Model 102A04 **OBSOLETE** See 102B04 High frequency ICP ... - PCB
Amplifier Seal Ring Potting Connector Preload Sleeve Electrodes Diaphragm Quartz Plates Housing 0.218 Dia Acceleration Compensation Mass and Plate Mounting Clamp Nut M. Drawing Number: 21075 Revision: B ECN Number: 41425 OPERATION MANUAL FOR QUARTZ PRESSURE SENSORS SERIES 102A, A03, A04, A06, A12, A15, A21, A22
Model 113B23 High frequency ICP® pressure sensor, 10k psi, 0.5 ... - PCB
ICP® source follower amplifier. These components are joined together as an inseparable sealed assembly at the factory. Disassembly should not be attempted in the field. Series 113B2are in a probe confix guration and are installed with a hollow clamp nut with 5/16-24 or M7x0.75 external threads. The housing of these
Model 113B27 High frequency ICP® pressure sensor, 100 psi, 50 mV ... - PCB
ICP® source follower amplifier. These components are joined together as an inseparable sealed assembly at the factory. Disassembly should not be attempted in the field. Series 113B2are in a probe confix guration and are installed with a hollow clamp nut with 5/16-24 or M7x0.75 external threads. The housing of these
A1 RELEASE NUMBER 30/NOV/18 ROOKIE ADDED DATE CODE FEATURE 4DEC24 JHEAD ...
a1 release number 30/nov/18 rookie of: sh: rev: dwg no: title: rev description date revisions eco by appr 3 1 a2 at04-12px-l012 12p receptacle, flange mount
Product Finder - Lutze Inc.
LUTZE Inc. 13330 South Ridge Drive • Charlotte, North Carolina 28273 • USA Phone: 704-504-0222 • Fax: 704-504-0223 • E-Mail: info (at) lutze.com
Model 102B03 High frequency ICP® pressure sensor, 10k psi, 0.5 ... - PCB
ICP® source follower amplifier. These components are joined together as an inseparable sealed assembly at the factory. Disassembly should not be attempted in the field. Series 113B2are in a probe confix guration and are installed with a hollow clamp nut with 5/16-24 or M7x0.75 external threads. The housing of these
Model 357B11 High temp., miniature (2 gm), ceramic shear, charge ... - PCB
externally by either a laboratory-style charge amplifier or in-line charge converter prior to being analyzed by a readout or recording device. The absence of built-in electronics permits operation to elevated temperatures of 500 °F (260 °C) for most ceramic crystal models and typically 900 °F (482 °C) and extreme application up to
Model 176M03 | PCB Piezotronics
When using Model EX682A40 or 421A30 differential charge amplifier, also use 045M21B cable. Replaces Legacy Model Endevco 522M37A-120. Measurement Range: 20 psi (1.4 bar) Sensing Element: UHT-12™ Temperature Range: -94 to 986 °F (-70 to 530 °C)
Model S112A21 High resolution ICP® pressure probe, 100 psi, 50 mV/psi ...
sensitivity of 50 mV/psi and a low noise amplifier of 50 V peak noise. Thus, 50 V/50mV = .001 psi resolution The output bias voltage of the Model 112A23 is 5.0 volts, half the bias voltage of most PCB pressure sensors. This will cause the bias monitor meter on PCB power supplies to read at the low end of the ...
Model 113B28 Platinum Stock Products; High frequency ICP ... - PCB
ICP® source follower amplifier. These components are joined together as an inseparable sealed assembly at the factory. Disassembly should not be attempted in the field. Series 113B2are in a probe confix guration and are installed with a hollow clamp nut with 5/16-24 or M7x0.75 external threads. The housing of these
Model 113B21 Platinum Stock Products; High frequency ICP ... - PCB
ICP® source follower amplifier. These components are joined together as an inseparable sealed assembly at the factory. Disassembly should not be attempted in the field. Series 113B2are in a probe confix guration and are installed with a hollow clamp nut with 5/16-24 or M7x0.75 external threads. The housing of these
Low Power Black Housing Cool White Pair A-Series
Support. Cables & Adapters. Mix and Match™ Cables 1kW; Mix and Match™ Cables 600W; Mix and Match™ CHIRP Cables; Transducer Identification. B744V/VL Newer Version
main | Precision Battery Monitor BMV-702
Precision Battery Monitor BMV-702. Support. Cables & Adapters. Mix and Match Cables 1kW; Mix and Match Cables 600W
Product Finder - Lutze Inc.
LUTZE Inc. 13330 South Ridge Drive • Charlotte, North Carolina 28273 • USA Phone: 704-504-0222 • Fax: 704-504-0223 • E-Mail: info (at) lutze.com
Model TLD086C03 Modally Tuned® Impulse Hammer w/force sensor and ... - PCB
3. Switch the power on, and wait a minute or two for the sensor amplifier to turn on and for the coupling capacitor to fully charge. Check the power unit’s meter for normal operation (e.g. meter pointer pointing in green area). 4. If a meter’s pointer points in the red area, look for shorted cables or connections. If a meter’s
Model S113B24 High frequency ICP® pressure sensor, 1000 psi, 5 ... - PCB
ICP® source follower amplifier. These components are joined together as an inseparable sealed assembly at the factory. Disassembly should not be attempted in the field. Series 113B2are in a probe confix guration and are installed with a hollow clamp nut with 5/16-24 or M7x0.75 external threads. The housing of these